2. Before normal use, perform a static load test at 125% of the rated load, lifting the hoist approximately 100 mm above the ground for 10 minutes to check for proper operation.
3. A dynamic load test involves repeated lifting and lowering and left-right movement at the rated load. After the test, check the mechanical transmission, electrical components, and connections for proper operation and reliability.